TCL TAC-09CSD handleiding

72 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 14 van 72
TCL Air Conditioner Service Manual
14
COMPRESSOR
ON
OUTDOOR FAN
4-way VALVE
OFF
50S
50S
43S
48S
Defrosting max time
43s
Defrosting end off: Compressor stops working, and re-starts to working after 50s delay;
7.Coldairprevention:
Thisfunctionintendstopreventcoldairfrombeingdischargedwhentheheatingoperationstartsup
1).IDUfanmotorcoldairprevention
.When RT24:
a.IfITP31 whilecompressorworksfor5min,fanmotorwillworkaccordingtopresetfanspeed.
b.IfIPT≤31,fanmotorstopsworkingwhilecompressoroperationwithin2min,ifIPT≥27,fanmotorworksinlow
speed2min,thenchangetopresetspeed.
WhenRT≥24:
a.Within2minaftercompressorstartupworking,onceIPT27,fanmotorwillchangetopresetspeed.
b.Aftercompressorstartsworking2min,fanmotorchangetopresetspeeddirectly.
2).Vanebladeoperationforcoldairprevention.
Ifthevaneworksonstatusofnon‐swing:WhileIPTincreasetoaspecialdegree,thevanebladewillchangetheposition
to:
Defaultangle;or
Previousposition;or
Customerpreset.
The above operation can work one time only, when compressor stops working, the unit will once again inspect the
function.
Ifthevaneworksonswing:WhenIDUquitsfromcoldairprevention,vaneoperateaspreset.
8. “8” Heating
When function effective, it will make sure the room temperature not lower than 8, unit works on heating mode.
4.1.5 Fan mode
1. The temperature setting: 16~31,
Fan speed and vane position: as preset. The function for remote controller 58E only.
2. For above function, when unit preset to be auto fan mode, the fan motor will change its operation speed based on
the temperature difference of ambient and preset temperature.
3. ODU always OFF.
4.1.6 Timer
The unit has times control, when the unit meet the timer preset, it will be switched on or off automatically.
TIMER ON
1). TIMER ON can be set only when the air conditioner is OFF.
2). Press TIMER on the remote control ONCE to enter time setting.
3). Press “▲” or “▼” to set the time for unit to start working.
4
2
0
2℃
4℃

Bekijk gratis de handleiding van TCL TAC-09CSD, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkTCL
ModelTAC-09CSD
CategorieAirco
TaalNederlands
Grootte10827 MB