INSTALLATION MANUAL---Information for the installer
32
Pipe length and Additional refrigerant
Inverter Models capacity (Btu/h)
9k-12k
18k-36K
Lenght of pipe with standard charge
Maximum distance between indoor and outdoor unit
Additional refrigerant charge
Max. diff. in level between indoor and outdoor unit
Type of refrigerant
15m
10m
20g/m
R22/R410A
3m
(North American:5m )
R32
15m
10m
15g/m
3m
(North American:5m )
25m
15m
30g/m
R22/R410A
5m
(North American:7.5m )
R32
25m
15m
25g/m
5m
(North American:7.5m )
ON-OFF Models capacity (Btu/h)
9k-12k
18k-36K
Lenght of pipe with standard charge
Maximum distance between indoor and outdoor unit
Additional refrigerant charge
Max. diff. in level between indoor and outdoor unit
Type of refrigerant
15m
5m
20g/m
R22/R410A
3m
(North American:5m )
R32
15m
5m
15g/m
3m
(North American:5m )
15m
5m
30g/m
R22/R410A
5m
(North American:7.5m )
R32
15m
5m
25g/m
5m
(North American:7.5m )
Dedicated Distribution Device and Wire for Air Conditioner
Maximum Operating Current
of Air Conditioner (A)
Nominal Specification
of Socket or Switch (A)
2.5
6.0
1.5
4.0
Note:
This table is only for reference, the installation shall meet the requirements of local laws and
regulations.
16
25
32
40
1.0
Reference Fuse
Specification
(A)
10 and 15
10
32
32
64
64
20
Minimum Wire
Cross-sectional
2
Area(mm )
15 and 24
24 and 28
28 and 32
0.75
8
10 20
8 and 10
Dedicated Distribution Device and Wire for Air Conditioner