Supermicro SuperServer AS -3015MR-H5TNR handleiding
Handleiding
Je bekijkt pagina 31 van 98

31
Chapter 3: Maintenance and Component Installation
2. Align the heatsink to the socket. With a Phillips #1 bit torque driver set to a force of 8.7
in-lbf (0.98 N-m), gradually secure the heatsink by starting with two screws on opposite
corners.When nished, the heatsink will be secured over the socket and processor
Important: Do not use a force greater than 8.7 in-lbf (0.98 N-m). Exceeding this force
may over-torque the screw, causing damage to the processor, heatsink, and screw.
(0.98 N-m), gradually secure the heatsink by starting with two screws on opposite
corners.When nished, the heatsink will be secured over the socket and processor.
3
4
5
6
7
8
9
1
0
1
1
IN-LBF
8.7
0.98
N-M
Bekijk gratis de handleiding van Supermicro SuperServer AS -3015MR-H5TNR, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Supermicro |
Model | SuperServer AS -3015MR-H5TNR |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 15816 MB |