31
Chapter 2: Installation and Setup
Checking the Temperature of an NVMe Drive
There are two ways to check using the BMC Dashboard.
Checking a Drive
BMC Dashboard > Server Health > NVMe SSD – Shows the temperatures of all NVMe
drives.
BMC Dashboard > Server Health > Sensor Reading > NVME_SSD – Shows the single
highest temperature among all the NVMe drives.
Installing M.2 Drives
1. Power down the node as described in Section 2.2.
2. Locate the plastic clips that will lock the M.2 SSD in place.
3. Determine whether your M.2 SSD is 80mm or 110mm. If the plastic clip is not in the
correct hole, move it.
a. To remove the plastic clip, twist it 90 degrees and pull up.
b. To insert the plastic clip, push it into the correct mounting hole and twist 90 degrees.
4. Insert the M.2 SSD sideways into the connector on the motherboard so that it lays at,
then secure it to the motherboard with the plastic clip.
5. Replace the blade and restore the power.