Part # 4523343 Rev 2 (03/04/10)Page 4
DIMENSIONS AND SPECIFICATIONS
Clearances
Clearances Applicable For All Models
Surface Sides Rear
Combustible Wall Minimum 14” (356mm) 6” (152mm)
Non-Combustible Wall Minimum 0” 0”
Gas Pressures
Gas
Minimum Supply
Pressure
Manifold Operating
Pressure
Natural 7” WC (17.5 mbar) 4.5” WC (11.25 mbar)
Propane 11” WC (28 mbar) 10” WC (25 mbar)
Gas Inlet Size
Model Width Connection
24” (610mm) &
36” (914mm)
3/4” NPT
Rear Gas Connection
60” (1524mm)
1” NPT
Rear Gas Connection
Individual Burner Input Rates
Burner
Input BTU/HR
Natural
Gas
Propane
Gas
Open Top 30,000 26,000
Hot Top Burner (In lieu of 2 open top burners) 18,000 18,000
Griddle Burner (In lieu of 2 open top burners) 18,000 18,000
Raised Griddle Broiler (Consists of 3 burners) 33,000 33,000
Oven Burner Standard 33,000 29,000
Space Saver Oven 25,000 25,000
Rates are for installations up to 2000’ (610m) above sea level