For a Harper-Wyman
regulator, remove
converter cap by inserting
a coin into slot in top and
twisting. Turn cap over
and re-install.
On the SCP regulator,
unscrew the converter
using a 5/8'' wrench. Turn
the cap over and reinstall.
On the Maxitrol regulator,
unscrew the brass converter cap
using a 7/8" wrench. Turn the
selector pin over and re-install.
To Convert and/or Adjust
1. Convertible Pressure Regulator
The inlet pressure of the gas supply shall be in accordance with the nominal inlet
pressure of the regulator used on the range or 1/2 psig maximum. The range should be
tested by pressurizing the regulator with an inlet pressure at least 1 inch water column
above the manufacturer's specied manifold pressure shown on the serial plate. The
range will be equipped with one of the two types of regulators shown.
Note: What you read on the converter cap or plunger is the type of gas for which the
regulator is set. If yours reads NAT, the regulator is set for natural gas. If yours reads
LP, the regulator is set for LP.
13
LPG
LPG
LPG
NAT
Maxitrol
Regulator
NAT
SCP
Regulator
NAT
Harper-Wyman
Regulator