Handleiding
Je bekijkt pagina 9 van 26

9
Built-in Under-counter Instructions
Make sure your installation does not block the front
ventilation grille. The unit is designed to fit under
worktops, using the height-adjustable ventilation grille to
ensure that the feet are concealed from front view.
If the unit is fully integrated to be installed for fitting
kitchen plinth, make sure that the ventilation gaps in the
plinth are at least 300 square centimeters and remove
the ventilation grilles, so that warm air can disperse
unhindered. Otherwise, the appliance has to work
harder, resulting in an increase in electricity
consumption.
NOTE: When pushing the appliance into the niche, make
sure that the mains cable does not get trapped.
Model No.
a
(Inch/mm)
b
(Inch/mm)
c
(Inch/mm)
A
(Inch/mm)
B
(Inch/mm)
C
(Inch/mm)
ASDR1524
32" / 813
18" / 455
14¾" / 375
32⅛" / 816
18" / 455
15" / 380
SDHDR1535
34" / 864
18" / 455
14¾" / 375
34⅛" / 866
18" / 455
15" / 380
ASDR2414
32" / 813
18" / 455
23½" / 595
32⅛" / 816
18" / 455
23⅝" / 600
SDHDR2446
34" / 864
18" / 455
23½" / 595
34⅛" / 866
18" / 455
23⅝" / 600
ADRD241
32" / 813
22½" / 570
23½" / 595
32⅛" / 816
22¾" / 575
23⅝" / 600
SPR627OS2D
34" / 864
24" / 608
23½" / 595
34⅛" / 866
24" / 608
23⅝" / 600
NOTE:
1. Models LADR1545, ASDR1554, SDR1529, LDR1549, SDDR1558 and DB2DRR1584ASD have
the same size as ASDR1524.
2. Model DB2DRR1585SD has the same size as SDHDR1535.
3. Models LADR2433, ASDR2444, SDR2418, LDR2437, SDDR2448 and DB2DRR2487ASD have
the same size as ASDR2414.
4. Model DB2DRR2488SD has the same size as SDHDR2446.
5. Models FF642DADA, LDR24A, ADFD243, SCFF532DADA, LDF24A, ADRF244,
SPRF2D24ADA, LDRF24A, ADFD243IM, ADRF244IM, DB2DRR2486ADA, DB2DFZ2474ADA,
DB2DRF2479ADA, DB2DFZIM2494ADA and DB2DRFIM2482ADA have the same size as
ADRD241.
6. Models FF642D, SCFF532D, SCFF532DIM, SPFF51OS2D, SPRF34D, SPRF34DIM,
SP6DS3D, SPR245OS3D, FF493D, DB2DRROS2489, DB2DFZ2475, DB2DFZIM2495,
DB2DFZOS2478, DB2DRF2481, DB2DRFIM2483 and DB3DRR2499 have the same size as
SPR627OS2D.
Anti-tip Bracket Installation
To reduce the risk of tipping the unit by abnormal usage or improper loading, the appliance must be
secured by properly installing the anti-tip device packed with the appliance.
• Place the anti-tip bracket on the floor as shown in the figure. An anti-tip bracket must be installed
at the left side.
• Mark the locations of the 4 holes of the anti-tip bracket on the floor.
• Use a 5/16” masonry drill bit and insert plastic anchors.
• Secure bracket to floor using screws.
• Slide appliance into position and make sure the leg engages the anti-tip bracket.
NOTE: If the unit is relocated, the bracket must be removed and installed in the new location.