TROUBLESHOOTING (TO BE PERFORMED BY STORE PERSONNEL) - PAGE 1 OF 2
CONDITION TROUBLESHOOTING
Water Is On
The Floor
Water on floor can cause extensive damage to flooring! Resolve immediately.
> For units with optional heated humidification system, check overflow (at rear of case).
See CASE DESIGN, CONT’D: POWERED HUMIDIFICATION SYSTEM / WATER
CAPACITY/TYPE section in manual for water capacity specifics. Important! You must
check overflow periodically (at least weekly) to make sure it is not going to overflow.
Also, to be able to always SEE overflow state, it may be a good practice to REMOVE
lower end panel!
> Check condition of BOTH the humidification system fill funnel hose and overflow
hose. If they are cracking or show fatigue, they must be replaced. Contact Structural
Concepts Corp. for replacement hose(s).
> Check connections (including quick-connects) and/or clamps on all hoses. If loose
or poorly connected, tighten securely.
• Access to water fill funnel connector is gained by lifting it up and off rear of case.
• Access to humidification system is gained by removing decking. Caution! You
must turn off power to case and allow to cool for 30 minutes before accessing
components under decking!
• See CASE DESIGN, CONT’D: POWERED HUMIDIFICATION SYSTEM / WATER
CAPACITY/TYPE After checking all the above, if water is still dripping onto floor,
call service provider.
Poor or No
Humidification
> Check that heating element works (on water inlet side).
> Check that float is functional. See CASE DESIGN, CONT’D: POWERED
HUMIDIFICATION SYSTEM / WATER CAPACITY/TYPE section in manual for location/
illustration. If it is malfunctioning call service provider.
> Humidity is to be adjusted based on product.
• Adjust humidity control by adjusting controller (at case rear).
• Raise humidity level one point at a time (e.g., if humidity level is at “5”, press the “up”
key to change it to “6”).
• See CASE DESIGN, CONT’D: MAIN POWER / LIGHTS / PRE-HEAT /
OPERATION / SHUTTING DOWN section specifics on adjusting humidity.
Fan Noise Is
Excessive
Call service provider.
Case is Not
Holding Proper
Temperature
If a large amount of cool (or ambient) product was added to the case, it will take time
for the temperature to adjust. Product must be pre-heated before placing in case.
See PROGRAMMABLE CONTROLLER INFORMATION section in this User Manual for
thermostat specifics.
• Check air return grilles (area at front of decking) for obstructions.
• DO NOT set product on air grilles as this will prevent proper airflow!
• See PRODUCT PLACEMENT / AIRFLOW CONSIDERATION / LOAD LINES
section in manual for product placement guidelines.
Check that the case is not in the sun. See OVERVIEW / THERMOMETER /
COMPLIANCE / WARNINGS / PRECAUTIONS section in this manual for specifics.
If case still is not holding proper temperature, call service provider.