TROUBLESHOOTING (TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY), PAGE 1 OF 2
CONDITION TROUBLESHOOTING
Water Is On The
Floor
Caution! If too much water fills humidification system, case is designed for water to
overflow at rear of case.
• IMPORTANT! If humidification system overfills, you must check overflow at
rear of case.
• IMPORTANT! If MAX CAPACITY light malfunctions, you must check overflow
periodically to assure that water does not overflow onto floor.
• IMPORTANT! If humidification system overfills, you must soak up excess
water from floor with sponge. Otherwise, water on floor can cause damage.
Fans Emit
Excessive Noise
Check that the case is aligned, level and plumb.
Check axial fans for cleanliness.
Check that fan motors are securely mounted in brackets.
Check that nothing is preventing blade rotation.
Check that the fan shroud is properly secured.
Fans Are Not
Working
Check that the MAIN power switch is on.
Check that fans are plugged.
Check for foreign material obstructing fan performance.
Check that fan blades freely rotate within fan shrouds
Check that power is going to fans
Check that fan wiring is connected on terminal blocks.