PREVENTIVE MAINTENANCE - TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY - 7 of 7
A
B
C
E
F
G
D
ANNUAL (OR AS NEEDED) PREVENTIVE MAINTENANCE INSTRUCTIONS
Honeycomb Air Diffuser:
A. Wedge a non-metallic device of suitable strength (such as a ballpoint pen) between honeycomb and its
housing. Caution! Use care not to dislodge the heating wire (that prevents condensation on the
honeycomb retainer).
B. Apply pressure to collapse honeycomb to pull it out of honeycomb retainer.
C. Carefully pry downward and away from the honeycomb retainer.
D. Use brush to reach in and, with outward sweeping motion, pull any crumbs or residue out of
honeycomb area.
> Clean honeycomb with warm water and soap solution. Submerse if necessary. Use brush to dislodge
stubborn or sticky residue. Dry by using vacuums blow mode.
E. After honeycomb has been thoroughly cleaned and dried, squeeze honeycomb to allow it to fit into the
honeycomb retainer.
F. Carefully slide honeycomb into place.
G. Adjust honeycomb so it fits flat against retainer (not be wavy or out of position).
WARNING! TURN OFF CASE BEFORE PERFORMING PREVENTIVE MAINTENANCE!