OVERVIEW, CONT’D
• This sheet details dangers due to flammable
refrigerant. It addresses operational area required,
case placement guidelines, child-proofing the unit
and refrigerant recycling and/or disposal, etc..
DANGER
• Please read section shown below for specifics on
risk of fire explosion, service guidelines, LFL, etc.
CAUTION
• This sheet also details the area required for operation,
areas to avoid placing case, guidelines for children (and
others with limited capabilities) while near box door cases.
• This sheet also provides information on refrigeration
recovery, recycling and disposal.
>> See next page for continuation.
OVERVIEW, CONT’D: DANGER (RISK OF FIRE OR EXPLOSION) / CAUTION (AREA, ETC.) - PAGE 2 of 4
CAUTION
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning use
of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
DANGER
• Refrigeration unit contains gas under high pressure. Do not tamper with or
puncture the system. Contact qualified service personnel before disposal.
• Risk of fire or explosion. Flammable refrigerant is used in this case.
• Consult repair manual/owner’s guide before servicing this product.
• Do not store explosive substances (such as aerosol cans with a flammable
propellant) in this appliance.
• Do not use an electrical appliance INSIDE the food storage compartments
unless its type is recommended by manufacturer.
• To minimize risk of ignition due to incorrect parts or improper service, this case
is ONLY to be serviced by factory authorized service personnel.
• Flammable refrigerant type specified on case nameplate is on serial label.
• Models BD3632 and BD4732 contain a charge of 150g of R290 refrigerant with a
lower flammability limit (LFL) of .038kg/m³.
CAUTION
≥7.1m²
CAUTION
Minimum room floor area required for operation of these box door cases is ≥7.1m².
CAUTION: REFRIGERANT RECOVERY/RECYCLING/DISPOSAL
• When recycling or discarding case, refrigerants MUST BE handled according to
local, state and federal codes, requirements and regulations.
• If disposing of a refrigerated case that uses ozone depleting chemicals in its
refrigeration system, make sure the refrigerant is removed by a qualified
service technician and properly disposed of.
• If you intentionally release refrigerant into the atmosphere, you may be subject
to fines or other penalties (under regulations mandated by environmental
regulators and/or legislative edict).
CAUTION
• These box door cases are NOT to be installed in lobbies or locations of egress,
such as hallways, public corridors.
• If case is placed in an enclosure or surrounding structure, keep all of the case’s
ventilation openings clear of obstructions.