TROUBLESHOOTING (BY TRAINED SERVICE PROVIDERS ONLY) - CONDENSING SYSTEM
CONDITION TROUBLESHOOTING
Head Pressure
Too High
Check that the condensing coil is not dirty or covered.
Check that condensing fans are working.
Check that refrigerant is not overcharged.
Perform sub-cooling check and verify that no contaminates are in system.
Check that liquid line filter dryer is not plugged.
Check that close-offs are intact (around condensing coil) and that air is not
recirculating.
Check that store ambient temperature isnt above maximum allowed. See
OVERVIEW / TYPE / COMPLIANCE / WARNINGS / PRECAUTIONS / WIRING /
PLUGS section in this manual.
Head Pressure
Too Low
Check if sight glass is flashing or showing low charge.
Check that suction pressure isnt too low.
Check that compressor reed valves arent bad. Look for high suction/low head
pressure. Perform pump-down.