Structural Concepts Harmony HMBC3 handleiding
Handleiding
Je bekijkt pagina 36 van 37

Integrated Electronic
Microprocessor Controller
Read And Save These Instructions - Page 3 of 3
Summary Table of Operating Parameters
CODE PARAMETER UOM* TYPE MINIMUM MAXIMUM DEFAULT
/c1 Calibration of probe 1 °C/°F C -20 20
/c2 Calibration of probe 2 °C/°F C -20 20
St Temperature set point °C/°F F r2 r1
rd Control delta °C/°F F 20 0.1
dl Interval between defrosts hours F 0 250
dt1 End defrost temperature, evaporator °C/°F F -50 200
dP1 Maximum defrost duration, evaporator min F 1 250
d6 Display on hold during defrost - C 0 2
dd Dripping time after defrost min F 0 15
d/1 Display of defrost probe 1 °C/°F F - -
/5
Select Celcius (°C) or Fahrenheit (°F)
flag C 0 1
Structural Concepts Corp., 888 E. Porter Rd · Muskegon, MI 49441
Ph: 231.798.8888 / Fax: 231-798-0393 / www.structuralconcepts.com
36
I:\Oper Manuals - PUB\Templates\Carel Controller\Carel Controller IR33.pub
This data derived from Carel Material: ir33 +030220441 - rel. 2.0 - 01.05.2006
For Case
Specific
Defaults
See Serial
Label
Located
Near
Electrical
Access
On Your
Case.
For
Additional
Technical
Information
Call
Structural
Concepts
Technical
Service
Dept. at
1(800)
433.9489
* Unit Of Measure
Bekijk gratis de handleiding van Structural Concepts Harmony HMBC3, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Structural Concepts |
Model | Harmony HMBC3 |
Categorie | Koelkast |
Taal | Nederlands |
Grootte | 10459 MB |