TROUBLESHOOTING (TO BE PERFORMED BY TRAINED SERVICE PROVIDERS)
CONDITION TROUBLESHOOTING
Water Is On The Floor Check that drain trap is free of debris.
Check that the drain hose is correctly positioned over floor drain.
Check store conditions.
• To prevent condensation in NSF/ANSI Type I environments, maximum
conditions are to be 55% relative humidity / 75° Fahrenheit.
• For NSF/ANSI Type II environments, maximum conditions are to be
55% relative humidity / 80° Fahrenheit.
• If you are unsure if your unit is classified as NSF/ANSI Type I or Type
II, see tag next to serial label on your case.
Fan Emits Excessive Noise Check that the case is aligned, level and plumb.
Check evaporator fans for cleanliness.
Unplug/power off fan motors. Check to determine whether faulty.
Check that fan motors are securely mounted in brackets.
Check that the fan shroud is properly secured.
Fans Are Not Working Check that fans are plugged in at the fan shroud.
Check for foreign material obstructing fan performance.
Check that fan blades freely rotate within fan shrouds
Check that power is going to fans (certified electricians only).
Check that fan wiring is connected on terminal blocks (certified
electricians only).
System Is Not Operating Check that the utility power is on.
Check the circuit breaker box for tripped circuits.