TXV Evaporator
Coils
Evap. Fan (Typ.)
Evap. Fan Shroud
1. Coil Fan Discharge
When Main Power Switch is turned on, refrigeration
section will energize (see CASE START-UP section
in this manual).
Evaporator coil fans should turn on. From inside
of the case, check for discharge air from fans to
confirm that they are functioning properly.
When the case is in a start up mode or has been
idle for a long period of time, the unit will require
75 minutes of run time to pull-down
temperature.
See below illustration.
2. TXV (Thermostatic Expansion Valve)
TXV is under access panel (at customer
front-right of case).
Decking must be removed for access.
See illustration below for location.
Note: Partially disassembled view below shown
for illustrative purposes only.
DECKING, EVAPORATOR COIL FAN DISCHARGE, TXV LOCATION
View of Case With Decking and End Panel
Removed for Illustrative Purposes Only
Note: Illustrations Shown May Not
Reflect Every Feature or Option of
Your Particular Case.