TROUBLESHOOTING - GENERAL - PAGE 2 of 2
CONDITION TROUBLESHOOTING
Case Is Not Holding
Temperature
If a large amount of warm product was added to the case, it will take time for
the temperature to adjust. Unit needs product to be pre-chilled.
Check that the discharge air grille is not disrupted or blocked by product.
Check that the case is not in the sun or near a heat or air-conditioning vent.
If case is located near front doors, temperature fluctuation can hinder unit’s
ability to maintain temperature. See OVERVIEW / CONDITION TYPE /
COMPLIANCE / WARNINGS / PRECAUTIONS / WIRING section in this
manual for specifics.
Case Lights Are Not
Working
Check that light switch is in the on position.
LED Lights: Check plugs and lights for proper connection (illustrated below).
Check for burned out bulbs. If so, turn lights off & replace.
Trained Service Providers Only: Check to insure voltage at ballasts. If voltage
is entering but not exiting ballast, ballast is faulty.
No Gap
Gap
LED Light
Plug
LED’s Barrel
Shaped Insert