REFRIGERATION LINES / STUB-UPS / DRAINS (REMOTE UNITS ONLY)
1. Refrigration Line Stub-Up Connections
Refrigerant stub-up access is at underside of
case.
Stub-up connections are accessed by removing
front or rear panel (no screws required).
Run case-to-case connections through cutouts in
base.
Sweat the high and low pressure connections.
Fill access hole with suitable filler to insure
watertight integrity of tub.
Note: Illustration below may not reflect every
feature or option of your particular case.
Refrigeration
Line Stub-Ups
Access
Field Connection
for Drain
Model GMSS1252R is Shown Above.
Your Case May Differ.
P-Trap
2. Drains
Depending upon model, cases have drains at left
and right hand sides.
Model shown below (GMSS1252R) has a single
drain (as shown below).
Drain field connection is as shown below. See
MAINTENANCE FUNDAMENTALS - DRAIN /
SHUT-OFF VALVE / BALANCE VALVE
ACCESS section in this manual for illustration of
Balance Valve, Shut-Off Valve, Drain,
Refrigeration Line Stub-Ups Access, etc.
Depending upon drain access needs, either front
or rear panel may be removed to gain access to
drain stub-up.
1.5” male PVC stub-up connection is under case.
Connect tub drain to floor drain. Maintain
1/4”-fall per foot to provide proper drainage.
Drain
Note: Illustration shown may not
exactly reflect every feature or
option of your particular case.