Structural Concepts Fusion GMGV4 handleiding
Handleiding
Je bekijkt pagina 39 van 43

39
TROUBLESHOOTING - GENERAL ISSUES (PAGE 3 of 3)
CONDITION TROUBLESHOOTING
Case Lights Are Not
Working
Check that light switch is in the ON position.
Check bulbs for proper installation and connection.
Check that light switch (if any) is in the on position.
Check for burned out bulbs. Turn lights off & replace.
Clean dirt and dust from the bulbs to prevent flickering.
Certified electricians only: Check voltage flow at ballasts. If voltage is entering but
not exiting the ballast, ballast is faulty.
>> T-8 fluorescent lights: Check that ALL lights are connected properly and
receptacles capped. See MAINTENANCE FUNDAMENTALS: REAR SLIDING
DOORS / T-8 LIGHT FIXTURES section in manual for illustrations and in-depth
instructions.
>> LED lights: Check that LED lights are connected properly. See
MAINTENANCE FUNDAMENTALS: LED LIGHT FIXTURES section in manual
for illustrations and in-depth instructions.