Warning! Disconnect power before providing
maintenance and service to unit.
Caution: Lamps are treated to resist breakage and
must be replaced with similarly treated lamps.
Note: Warranty will be void if claims arise from
negligence, misuse of goods, extreme environmental
conditions or improper maintenance. See Overview
And Warnings section in manual.
2. Rear Sliding Doors
Note: Doors are not interchangeable. There is an inner
and outer door. Outer door must be removed first and
replaced last.
• The outer door is the right hand door (from service
side or rear of case).
• Move doors toward the center of the case.
• Individually lift each door up toward the top of the
case; pivot the bottom of the door out.
• Replace rear sliding doors in reverse order they were
removed.
3. Light Fixtures
Note: Depending upon model and options, light fixtures
can have either single or dual lamps.
Light fixtures are located on underside of shelf
assemblies and at the top inside of case. See illustration
at upper right for locations.
Removal of lamps:
• Rotate lamp (1/4-turn) to disengage (upper or lower)
pins/contacts from mounting sockets.
• Remove bulb by applying even pressure from back
side at the bulb ends and pulling the remaining
contact from sockets.
• See illustrations at mid and lower-right.
Installation of lamps:
• Align pins with slot.
• Insert pins into socket by rotating the bulb 1/4-turn to
secure either the (upper or lower) pin contacts into
the sockets.
• Rotate remaining bulb contacts (1/4-turn) into
remaining lamp mounting socket contacts.
• See illustrations at right.
4. Supplemental Flood Lighting / Food
Lighting Specifics / Cautionary Note
• Avoid using supplemental flood or spot lighting.
• Display light intensity has been designed for
maximum visibility and product life at the factory.
MAINTENANCE FUNDAMENTALS, CONT’D: REAR SLIDING DOORS / T-8 LIGHTS / FLOOD LIGHTS
Light
Fixtures
• Caution! The use of higher output
fluorescent lamps (H.O. and V.H.O.), will
shorten the shelf life of the product,
causing ‘product browning.’
• Bulbs must be replaced with similar wattage,
output and design as those in which the unit
was equipped with from the factory.
>> See next page for LED light fixture
information.