INSTALLATION, CONT’D: REFRIGERATION LINES / STUB-UPS / DRAINS
Note: Model GMDSV6R.7115C (model
shown) may not reflect every feature or
option of your particular unit.
10. Refrigration Line Stub-Up Connections
Refrigerant stub-up access is at underside of
case.
Stub-up connections are accessed by removing
rear panel (no screws required).
Run case-to-case connections through cutouts in
base.
Sweat the high and low pressure connections.
Fill access hole with suitable filler to insure
watertight integrity of tub.
Note: Illustration below may not reflect every
feature or option of your particular case.
Refrigeration Line
Stub-Ups Access
Field Connection
for Drain
P-Trap
11. Drains
Cases have drains at left and right hand sides.
Longer cases may have drain at case center.
Drain field connection location as shown.
See next page for illustration of TXV Valve,
Drains, Refrigeration Line Stub-Ups Access, etc.
Depending upon drain access needs, either front
or rear panel may be removed to gain access to
drain stub-up.
1.5” male PVC stub-up connection is under case.
Drain stub-up may be at case center in extended
length cases.
Connect tub drain to floor drain. Maintain
1/4” fall per foot to provide proper drainage.