TROUBLESHOOTING - TO BE PERFORMED BY STORE PERSONNEL (UNLESS NOTED OTHERWISE)
CONDITION TROUBLESHOOTING
Not Holding Temperature If a large amount of warm product was added to the case, it will take time for
the temperature to adjust. Unit needs product to be pre-chilled.
Temperature changes during defrost mode but will return to normal. Fourth
LED will indicate defrost cycle in progress.
Check that case is not in sun or near a heat or air-conditioning vent.
If case is located near outside doors, temperature fluctuation can hinder units
ability to maintain temperature.
Check that condenser coil has been cleaned.
Check air return grilles for obstructions.
Trained Service Providers Only: Check sight glass for flashing and/or low
charge.
Trained Service Providers Only: Check set point temperature; it may be
adjusted too high.
Condensing Unit Is Not
Operating
Check that the power is turned on.
Determine if temperature controller settings are properly set. See your cases
serial label for your models specified settings. See SERIAL LABEL
LOCATION & INFORMATION LISTED / TECH INFO & SERVICE section in
manual for label location, etc.