MAINTENANCE FUNDAMENTALS, CONT’D: DRAIN / TXV VALVE ACCESS
3. Drain and Expansion Valve Access
The drain and expansion valve are both accessible from the front of the case.
Unplug the fans (one plug per side) and remove the fastener from the access panel in the front right
(or left) corner of the unit.
The drain and the expansion valve (TXV) is directly below the access panel.
Fan Plug
(Typical)
Evaporator
Fan
Model GMDS8R is Shown Above
With Pans & Shelf Removed.
Your Case May Differ
Evaporator
Fans
Drain
TXV Valve
Refrigeration
Lines
Note: Illustration shown may not
exactly reflect every feature or
option of your particular unit.