INSTALLATION: DISPLAY CASE START-UP / LIGHTS / THERMOMETER / TEMP. CONTROLLER
15. Case Start-Up
Case will power-up when properly field wired (or
plugged in).
After case is powered up, lift decking by simply
lifting up (no screw removal required) to confirm
that axial fans are running.
See next page for illustrations.
16. Light Fixtures
Light fixtures are located above honeycomb air
diffuser (as shown at right).
Warning! Disconnect power before providing
maintenance and service to unit.
Caution: Lamps are treated to resist breakage;
replace with similarly treated lamps.
Mini-LED Style Light Fixtures
Removal of lamp:
If case is provided with mini-LED lights, they will
rarely require change-out.
Contact Structural ConceptsTechnical Service
Department for replacement parts (see the
Technical Service section of operating manual).
Replacement of lamp:
To replace LED light fixture, simply disconnect the
existing LED light from its brackets. Replace.
Note: LED light and plug must be connected in a
specific manner or they will not work.
Make certain oval edge of plug connects to oval
edge of LED light.
See illustrations at right.
17. Light Switch
Turn on lights with switch located near
thermometer (as shown below).
To conserve energy, turn off lights when not
needed.
18. Thermometer
Thermometer is located near LED light switch.
Thermometer does NOT reflect actual food
temperatures; it is ONLY for monitoring warmest
air temperature in merchandiser.
Food probes must be used to measure actual
food temperatures.
19. Temperature Controller
Temperature controller is located at front left
behind lower front panel.
Temperature controller is provided by customer.
LED Light
Switch
Mini-LED Light
Thermometer
Dixell®
Display
See store manager for operating instructions for
your units temperature controller (thermostat).
Check that compressor symbol light is on.
Compressor will likely be identified with:
After case has run for a few minutes, check that
temperature starts to drop.
If temperature controller does not begin cooling
unit (in a few minutes) see temperature controller
owners manual for instructions.
LED Light
Plug
LEDs Barrel
Shaped Insert