Structural Concepts Fusion GJDSS4RLB handleiding
Handleiding
Je bekijkt pagina 23 van 25

23
MAINTENANCE FUNDAMENTALS - HONEYCOMB AIR DIFFUSERS (SERVICE TECHNICIANS ONLY)
Honeycomb Air Diffuser Access
See PREVENTIVE MAINTENANCE (TO BE PERFORMED BY
TRAINED SERVICE PROVIDER) section in this operating
manual for cleaning frequency.
A. Reach into edge of honeycomb bracket. Force honeycomb
away from lower lip of honeycomb bracket and grasp firmly.
B. Carefully pull honeycomb bracket outward (away from case
magnets). See image at right.
C. Remove entire bracket (with honeycomb inside) from case.
D. Clean honeycomb with warm water and soap solution.
Submerse if necessary. Use brush to dislodge stubborn or
sticky residue. Dry by using vacuum’s blow mode.
E. Replace honeycomb into honeycomb bracket so that it is
flat
against retainer. It must not be wavy or out of position.
F. Return honeycomb bracket to case (pressing it against
magnets in upright).
Note: For honeycomb air diffusers in other locations, these same
general instructions apply.
Magnet (To Retain
Honeycomb Bracket)
At Both Ends of Case
Removable Honeycomb
Bracket (Held To Case Via
Magnets at Each End)
Honeycomb
(Shown Removed
From Case)
--- View of Partially Disassembled Case ---
Bekijk gratis de handleiding van Structural Concepts Fusion GJDSS4RLB, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Structural Concepts |
Model | Fusion GJDSS4RLB |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 7913 MB |