CONDITION TROUBLESHOOTING
Case Lights Are Not
Working
Check that light switch is in the on position.
Check that ALL of the light cords and plugs are properly connected. See
INSTALLATION: DISPLAY CASE START-UP (START-UP / LIGHTS /
THERMOMETER / CONTROLLER) section in this operating manual.
Service Technicians Only: Check voltage at LED drivers. If voltage is entering but
not exiting, LED driver may be faulty.
Control Display Is
Flashing
See your cases serial label for your models specified settings. See SERIAL
LABEL LOCATION & INFORMATION LISTED / TECH INFO & SERVICE for label
location, etc.
Case Is Not Holding
Temperature
If a large amount of warm product was added to the case, it will take time for the
temperature to adjust. Unit needs product to be pre-chilled.
Temperature changes during defrost mode but will return to normal. Fourth LED
will indicate defrost cycle in progress.
Check that case is not in sun or near a heat or air-conditioning vent. See
OVERVIEW / TYPE 1 vs. 2 / COMPLIANCE / WARNINGS / PRECAUTIONS /
WIRING / PLUGS section in manual for adverse conditions/spacing issue
parameters.
If case is located near front doors, temperature fluctuation can hinder units ability
to maintain temperature. See OVERVIEW / TYPE 1 vs. 2 / COMPLIANCE /
WARNINGS / PRECAUTIONS / WIRING / PLUGS section in manual for adverse
conditions/spacing issue parameters.
Check air return grilles for obstructions.
TROUBLESHOOTING (TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY) - PAGE 2 of 2