CONDITION TROUBLESHOOTING
Case Not Lining
Up
See INSTALLATION section in this manual for instructions on properly aligning case
(alongside other cases) and adjusting levelers.
Water Is On The
Floor
Caution! Water on flooring can cause much damage! Until cause is determined (and
repaired), following these procedures:
Use wet-dry vacuum (or mop & bucket) to remove standing water.
Use catch pansfor water to drain into. Swap out regularly until case has
completely drained.
Note: See Drain, Hose and Bracket Placement Illustrations sheet in this manual for
views of different condensate systems used in display cases.
Check that the drain trap is free of debris.
Check that the drain hose is correctly positioned over condensate pan (or floor drain,
for remote units).
Check store conditions.
To prevent condensation in NSF/ANSI Type I environments, maximum conditions
are to be 55% relative humidity / 75° Fahrenheit.
For NSF/ANSI Type II environments, maximum conditions are to be 55% relative
humidity / 80° Fahrenheit.
If you are unsure if your unit is classified as NSF/ANSI Type I or Type II, see tag
next to serial label on your case.
TROUBLESHOOTING (TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY) - PAGE 1 of 3