CONDITION TROUBLESHOOTING
Case Lights Are Not
Working
Check that light switch is in the on position.
Check that ALL of the light cords and plugs are properly connected. See
MAINTENANCE: LED LIGHT REMOVAL/REPLACEMENT, PLUG/CORD
CONNECTION section in this manual.
Service Technicians Only: Check voltage at LED drivers. If voltage is entering but
not exiting, LED driver may be faulty.
Control Display Is
Flashing
See your case’s serial label for your model’s specified settings. See SERIAL
LABEL LOCATION & INFORMATION LISTED / TECH INFO & SERVICE for label
location, etc.
Case Is Not Holding
Temperature
If a large amount of warm product was added to the case, it will take time for the
temperature to adjust. Unit needs product to be pre-chilled.
Temperature changes during defrost mode but will return to normal. Fourth LED will
indicate defrost cycle in progress.
Check that case is not in sun or near a heat or air-conditioning vent. See
OVERVIEW AND WARNINGS section in manual for adverse conditions/spacing
issue parameters.
If case is located near outside doors, temperature fluctuation can hinder unit’s
ability to maintain temperature. See OVERVIEW AND WARNINGS section in
manual for adverse conditions/spacing issue parameters.
Check that condenser coil has been cleaned.
Check air return grilles for obstructions.
TROUBLESHOOTING (TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY) - PAGE 3 of 3