6
INSTALLATION, CONT’D: FIELD ACCESS WIRING CONNECTIONS/ SWITCHES / THERMOMETERS
Gain access to field wiring / electrical raceway by
removing front panel (removal of screws is required).
4. Field Access Wiring Connections
Field wiring connection location is at customer-right,
at underside of raceway (as shown below).
5. Lamp Power Switch
• Lamp switch is at customer-right.
• One (1) lamp switch controls all bulbs in unit.
6. Single vs. Three-Phase Selector Switch
• Both single phase field wiring leads AND three
phase field wiring leads are provided.
• Phase selector switch (see location below) must
match field wiring.
• Note: Depending upon options chosen, phase
selector switch lockout bracket may be standard.
Lamp
Switch
Terminal Block
Phase Selector Switch
(1-Phase vs. 3-Phase)
Terminal Block
50-Amp
4-Pole Lever
Main Power Switch
If not, optional phase selector switch lockout
bracket (SCC P/N 20-35413) is available.
7. 50-Amp 4-Pole Lever Main Power Switch
• See illustration below.
• Power to all lights AND heated shelves is shut off
when this switch is turned off.
8. Thermometers
• Thermometers in equipment reflect internal air
temperature only (not actual food temperature).
• Use probe thermometers to determine actual
product temperatures.
• See Vapor Thermometer section in manual for
temperature dial design and range.
Vapor
Thermometer