INSTALLATION, CONTD: CASTER STYLES / LOCKING & UNLOCKING / RAISING & LOWERING
Caster Styles - Overview
>> Structural Concepts utilizes two (2) different caster
styles on its merchandisers.
>> Both caster styles are illustrated on this page.
13. Caster Style A- Locking/Unlocking Only
Caster Style Ais shown at top right on this page.
Case must be level and plumb before locking;
levelers are usually adjusted to do so; see previous
page for leveler adjustment instructions..
Caster assembly Style Ais identified as having a
frontand rearfor these instructions.
To lock caster, press down caster lever at rear.
To unlock caster, press down caster lever at front.
This style of caster cannot be raised or lowered.
14A. Caster Style B- Locking/Unlocking
Style Bcasters are unlocked at shipment
(as casters are held in place by wooden
blocks and metal brackets).
Style Bcasters are in unlocked position;
caster levers will be parallel to floor.
After case has been moved into position,
casters may be locked. To do so, press
downward against the ONmarking on the
caster lever.
To unlock casters (and move case to a
different location), press downward against
the OFFmarking on the caster lever.
Casters will now be unlocked, allowing the
case to be moved.
See caster/lever illustrations at lower right for
specifics.
14B. Caster Style B- Raising/Lowering
Style Bvertical height adjustment ring
illustrations are shown at mid and lower right on
this page.
Style Bcaster are utilized in lieu of levelers.
Cases are shipped from factory with Style B
casters RAISED to maximum height; this position
aids in skid removal.
After case has been moved into position, Caster
Style Ballows vertical adjustment of case so it
may be adjusted until case is level and plumb.
Slotted head screws MAY be tightened/loosened to
lock vertical height adjustment ring; usually, these
Slotted head screws are NOT tightened at factory.
After case is level and plumb (as described on
previous page), must may be locked.
Caster
Vertical Height
Adjustment Ring
Caster Style B - Raising/Lowering
Locked
Caster Style A - Locking/Unlocking
Front of Caster
Assembly
Unlocked
Rear of Caster
Assembly
Caster Lever
Caster May Be Locked By
Pressing Downward
Against The ON Lever).
Caster Style B - Locking/Unlocking
Caster Lever Is Shown
In Unlocked Position.
Slotted Head Set
Screws May Be
Tightened When
Desired Vertical
Height Is Achieved)