Stiebel Eltron FCR 28/120 handleiding
Handleiding
Je bekijkt pagina 21 van 124

ENGLISH
www.stiebel-eltron.com FCR 28 | 21
INSTALLATION
Settings
Appliance handover
f Explain the functions of the appliance to the user. Show the
user how to operate the appliance.
f Make users aware of potential dangers.
f Hand over these instructions.
10.2 Recommissioning
See chapter “Initial start-up”.
11. Settings
11.1 Temperature
Appliance type with temperature selector inside the control
panel
85°C
60°C
35°C
26�02�79�0028
f The temperature is variably adjustable.
f Factory setting 60°C (the temperature selector clicks into
place at this setting).
12. Troubleshooting
Fault Cause Remedy
The water does not
heat up.
The high limit safety cut-
out has responded because
the controller is faulty.
Replace the thermostat and
press the high limit safety
cut-out reset button.
The high limit safety cut-
out has responded because
the temperature has fallen
below -15°C.
Press the reset button.
A heating element is faulty.
Replace the heating ele-
ment or flanged immersion
heater.
The high limit safety cut-
out has responded because
an indirect coil in the same
cylinder is set too high.
Limit the maximum tem-
perature of the indirect
coil.
The safety valve drips
when heating is
switched off.
The valve seat is contam-
inated.
Clean the valve seat.
D0000117439
High limit safety cut-out reset button
13. Maintenance
WARNING Electrocution
Before any work on the appliance, disconnect all poles
from the power supply.
13.1 Checking the safety assembly
f Check the safety assembly regularly.
13.2 Cleaning and descaling the appliance
f Never use descaling pumps.
f Only descale the flanged immersion heater after dismantling
and never treat the cylinder surface or signal anode with
descaling agents.
For the torque of the flange screws, see chapter “Specification/
Dimensions and connections”
13.3 Replacing the heating elements and protective
pipe
f Install the electrically insulated heating element and protec-
tive pipes into the flange plate.
!
Property damage
The corrosion protection resistor must not be damaged
or removed during maintenance work.
Bekijk gratis de handleiding van Stiebel Eltron FCR 28/120, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Stiebel Eltron |
| Model | FCR 28/120 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 20189 MB |