Stiebel Eltron FCR 28/120 handleiding

124 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 21 van 124
ENGLISH
www.stiebel-eltron.com FCR 28 | 21
INSTALLATION
Settings
Appliance handover
f Explain the functions of the appliance to the user. Show the
user how to operate the appliance.
f Make users aware of potential dangers.
f Hand over these instructions.
10.2 Recommissioning
See chapter “Initial start-up”.
11. Settings
11.1 Temperature
Appliance type with temperature selector inside the control
panel
85°C
60°C
35°C
26�02�79�0028
f The temperature is variably adjustable.
f Factory setting 60°C (the temperature selector clicks into
place at this setting).
12. Troubleshooting
Fault Cause Remedy
The water does not
heat up.
The high limit safety cut-
out has responded because
the controller is faulty.
Replace the thermostat and
press the high limit safety
cut-out reset button.
The high limit safety cut-
out has responded because
the temperature has fallen
below -15°C.
Press the reset button.
A heating element is faulty.
Replace the heating ele-
ment or flanged immersion
heater.
The high limit safety cut-
out has responded because
an indirect coil in the same
cylinder is set too high.
Limit the maximum tem-
perature of the indirect
coil.
The safety valve drips
when heating is
switched off.
The valve seat is contam-
inated.
Clean the valve seat.
D0000117439
High limit safety cut-out reset button
13. Maintenance
WARNING Electrocution
Before any work on the appliance, disconnect all poles
from the power supply.
13.1 Checking the safety assembly
f Check the safety assembly regularly.
13.2 Cleaning and descaling the appliance
f Never use descaling pumps.
f Only descale the flanged immersion heater after dismantling
and never treat the cylinder surface or signal anode with
descaling agents.
For the torque of the flange screws, see chapter “Specification/
Dimensions and connections”
13.3 Replacing the heating elements and protective
pipe
f Install the electrically insulated heating element and protec-
tive pipes into the flange plate.
!
Property damage
The corrosion protection resistor must not be damaged
or removed during maintenance work.

Bekijk gratis de handleiding van Stiebel Eltron FCR 28/120, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkStiebel Eltron
ModelFCR 28/120
CategorieNiet gecategoriseerd
TaalNederlands
Grootte20189 MB