a(1.735)
h= a-b = 1.735-1.224=0.511m
b(1.224)
h
l /2 l /2
DISTANCE MEASUREMENT
1) Position the rule at the measuring point to which the
distance is to be measured.
2) Aim the device and take the measurement, then read
the values from the upper and lower line of the ruler
cross-hairs. The reading unit is cm. Determine the
dierence between the top and bottom lines.
3) The distance marked in the drawing as "l" is
expressed in meters. 1 cm determined during the
measurement corresponds to 1 m distance between
the device and the measuring point.
2) Press the tripod legs into the ground (as shown in
the drawing below).
3) Place the leveller on the tripod and fasten it by
tightening the "B" locking screw (visible in the
drawing in sec. 1).
LEVELLING AND FOCUSING THE LEVELLER
1) Level the leveller by adjusting the screws (8) until the
bubble inside the vial (12) is centrally located.
2) To focus, aim the leveller towards the levelling rule,
then look through the viewnder (10) and keep
turning the focusing knob (6) until the image is in
focus.
3) Keep looking through the viewnder and rotate the
micrometer screw (7) until you have aimed at the
centre of the ruler.
3.3. DEVICE USE
3.3.1. MAKING MEASUREMENTS
Note! When positioning the rule at the measuring point,
always use a striding level to obtain a vertical position.
Incorrect adjustment of the rule may cause erroneous
measurements.
Level the device and set it in focus before each
measurement.
HEIGHT MEASUREMENT
1) Position the device centrally between points A and B.
2) Position the rule in point A and aim the device. Make
the measurement and read the value "a" on the
middle line of the cross-hairs on the rule.
3) Set the rule in point B and aim the device. Make the
measurement and read the value "b" on the middle
line of the cross-hairs on the rule.
4) Calculate the height dierences by subtracting the
values "a" and "b" from each other. Example:
l [m]
l [cm]
l
ANGLE MEASUREMENT
1) To determine the angle between points A and B, rst
position the rule in point A.
2) Aim the device at the rule positioned in point A and
read the value indicated by the horizontal circle (the
value is indicated by marker (9)).
3) Aim the device at the rule positioned in point B and
read the value indicated by the horizontal circle.
4) The dierence between readings is the angle
between points A and B.
3.3.2. ADJUSTING THE DEVICE
CHECKING THE VIAL
1) Using the levelling screws (8), level the device so that
the bubble is in the canter of the vial.
2) Turn the device 180°, the bubble should still be in the
centre of the vial. Otherwise, make adjustments.
3) Use a hexagonal key to gently turn the screws on
both sides of the vial thus changing the bubble
position. In this way, place the bubble in the centre
of the vial.
4) After positioning the vial bubble in the centre, turn
the device 180° again. If the bubble moves, adjust
again. Repeat these steps until the bubble remains
invariably in the centre.
LEVELLING THE AIMING LINE
1) Establish two measuring points A and B spaced
from 30 to 50 m apart. Position the device centrally
between the measuring points.
B
A
10
13
11
12
1. Base
2. Horizontal wheel
3. Eyepiece
4. Eyepiece cover
5. Lens
6. Focusing knob
7. Lateral micrometer screw
8. Levelling screw
9. Marker for horizontal wheel readings
10. Sight (collimator)
11. Vial mirror
12. Circular vial
13. Compensator lock
3.2. PREPARING FOR USE
MOUNTING THE LEVELLER ON THE TRIPOD
Note! The tripod is not provided with some models, you
can buy it as a separate item.
1) Fold out the legs of the tripod and spread it to the
preferred height, lock the setting by turning the "A"
screws.
Read instructions before use.
To increase the product life of the device and to ensure
trouble-free operation, use it in accordance with this user
manual and regularly perform maintenance tasks. The
technical data and specications in this user manual are
up to date. The manufacturer reserves the right to make
changes associated with quality improvement.
LEGEND
DO NOT USE THE DEVICE UNLESS YOU HAVE
THOROUGHLY READ AND UNDERSTOOD THIS
USER MANUAL
The terms "device" or "product" are used in the warnings
and instructions to refer to "Levelling set, Levelling
instrument".
a) Do not use the device in a potentially explosive
environment, for example in the presence of
ammable liquids, gases or dust.
b) If you discover damage or irregular operation,
immediately switch the device o and report it to a
supervisor without delay.
c) If there are any doubts as to the correct operation
of the device, contact the manufacturer's support
service.
d) Only the manufacturer's service point may repair the
device. Do not attempt any repairs independently!
e) Please keep this manual available for future
reference. If this device is passed on to a third party,
the manual must be passed on with it.
f) Keep packaging elements and small assembly parts
in a place not available to children.
g) Keep the device away from children and animals.
h) The device is not a toy. Children must be supervised
to ensure that they do not play with the device.
i) When not in use, store in a safe place, away from
children and people not familiar with the device who
have not read the user manual. The device may pose
a hazard in the hands of inexperienced users.
j) Keep the device in perfect technical condition.
k) Device repair or maintenance should be carried out
by qualied persons, only using original spare parts.
This will ensure safe use.
l) To ensure the operational integrity of the device, do
not remove factory-tted guards and do not loosen
any screws.
m) It is forbidden to interfere with the structure of
the device in order to change its parameters or
construction.
n) Keep the device away from sources of re and heat.
o) Do not direct the lens towards strong light sources
p) In order to obtain correct measurements, set the
device on an even and vibration-free ground.
q) Do not use the extended rule near power lines,
electrical tractions, etc.
r) Protect the device from falls, impacts, ooding,
oil contamination, etc. to ensure the quality and
accuracy of measurements.
s) Secure the device from shocks during transport.
3. USE GUIDELINES
The device is designed to measure the height dierence
between terrain points and to measure distance and
inclination angle.
The user is liable for any damage resulting from
unintended use of the device.
3.1. DEVICE DESCRIPTION
The original operation manual is written in German. Other
language versions are translations from the German.
2. USAGE SAFETY
PLEASE NOTE! Drawings in this manual are for
illustration purposes only and in some details may
dier from the actual product.
ATTENTION! Read all safety warnings and all
instructions. Failure to follow the warnings and
instructions may result in serious injury or even
death.
5
4
2
3
1
9
7
8
6
using state-of-the-art technologies and components.
Additionally, it is produced in compliance with the most
stringent quality standards.
Bekijk gratis de handleiding van Steinberg SBS-LIS-28/36, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Steinberg |
| Model | SBS-LIS-28/36 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 4553 MB |