Steinberg SBS-LI-125 handleiding

166 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 34 van 166
1. The display on the panel [4] reads the temperature limit which triggers the
alarm.
2. Operate the buttons [22] and [23] to set the temperature.
3. After several seconds of no interaction by the user, the appliance will save
the settings and revert to normal operation.
4. Press and hold the button [22] and [23] together for 3 seconds to read the
actual temperature measured. To revert to normal operation, briefly press the
button [22] or [23].
5. If the panel [4] display reads “ A ” with the temperature limit value, the
actual temperature has reached the limit and the alarm is triggered. The
appliance beeps and stops the heater.
6. Press and hold the button [22] and [23] together for 6 seconds to enter the
internal settings menu for the temperature limit. Enter the password “3”.
Press the button [23] to confirm.
USER-MODIFIABLE PARAMETERS:
Displayed
message
Parameter
designation
Function
(setting range)
Factory setting
Pb
Temperature
variation offset
Applicable to
low
temperature
deviations
Pb = actual
temperature
PV
(-50 50
o
C)
0
o
C
PL
Temperature fall
offset
Applicable to
high
temperature
deviations
PL = 1000 x
(actual value
PV) / PV
(-199 199)
0
SPH
Maximum attainable value
(0 400)
400