Steinbach Silent 9 handleiding
Handleiding
Je bekijkt pagina 27 van 30

52 53
049311_049312_049313_049314_049315_V2404 049311_049312_049313_049314_049315_V2404
en en
Troubleshoong
Problem: Cause: Soluon:
The heat pump does not switch on. The heat pump was installed
incorrectly.
Contact an authorized specialist.
The fuse of the protecve device
in the mains cable has blown or
an all-pole protecve device has
blown.
Reset the switch.
Replace the fuse.
The heat pump does not start. The three minutes required to
start the heat pump have not
minutes required to start the heat
pump have not elapsed.
Wait three minutes.
The temperature of the pool
water is approximately the same
as the set brine temperature.
The heat pump operates when the
water temperature is not equal to
the set target temperature.
The operang mode of the heat
pump is set incorrectly
Set the required operang mode.
The heat pump works, but the
water is not heated.
The heat pump has just been
installed.
Wait 24-48 hours unl the set
temperature is reached.
The pool water has cooled down
considerably since the last me
the heat pump was used.
Wait 24-48 hours unl the set
temperature is reached.
There is ice on the heat exchanger. The ambient temperature is too
low and/or there is a high level of
humidity.
Wait unl the automac defrost
defrost funcon (defrost) starts.
Leakage of the heat pump Accumulaon of condensaon. Set the heat pump to standby.
If the leakage stops, it is
condensaon water.
Leakage of water at the heat
exchanger or at the connecons
of the water circuit.
Check all connecons, pipes and
heat pump for leaks.
If the fault cannot be reced, please contact an authorized specialist or the Steinbach support team.
Error message display
Error code: Cause: Soluon:
E 03 Water ow rate too low Increase the pool water ow
through the heat pump.
Check the pump that pumps pool
water through the heat pump.
E 04 Defrosng Wait unl the heat pump has com-
pleted the automac defrosng
process has been completed.
E 05 Pressure in the coolant circuit too
high
Contact an authorized specialist or
the Steinbach Support Team.
E 06 Pressure in the coolant circuit too
high
Contact an authorized specialist or
the Steinbach Support Team.
E 09 Communicaon error Contact an authorized specialist or
the Steinbach Support Team.
E 10 Communicaon error Contact an authorized specialist or
the Steinbach Support Team.
E 12 Temperature sensor error:
Compressor coolant circuit too high
If the pool water temperature is
too high, reduce the setpoint.
E 15 Temperature sensor error: Water
inlet
Contact an authorized specialist or
the Steinbach Support Team.
E 16 Temperature sensor error:
Coolant circuit
Contact an authorized specialist or
the Steinbach Support Team.
E 18 Temperature sensor error:
Compressor output
Contact an authorized specialist or
the Steinbach Support Team.
E 20 ** Frequency inverter module error Contact an authorized specialist or
the Steinbach Support Team.
E 21 Ambient temperature sensor error Contact an authorized specialist or
the Steinbach Support Team.
E 23 Cooling mode: water output
temperature too low
Increase the set temperature in
cooling mode.
E 27 Temperature sensor water output
error
Contact an authorized specialist or
the Steinbach Support Team.
E 28 Fan motor error Contact an authorized specialist or
the Steinbach Support Team.
E 29 Return temperature coolant error Contact an authorized specialist or
the Steinbach Support Team.
E 32 Heang operang mode: water
output temperature too high
Lower the setpoint temperature in
heang operang mode.
E 33 Cooling operang mode:Coolant
circuit too hot.
Increase the set temperature in
cooling operang mode.
Carefully clean the ns of the heat
exchanger to remove any dirt.
If the fault cannot be reced, please contact an authorized specialist or the Steinbach support team..