Steinbach Silent 9 handleiding

30 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 22 van 30
42 43
049311_049312_049313_049314_049315_V2404 049311_049312_049313_049314_049315_V2404
en en
Display
Standby-Mode
In standby mode, the heat pump is ready for operaon but deacvated. The water is neither heated nor cooled.
By pressing the buon On/O
12
the heat pump switches between standby mode and operang mode.
Acve display elements:
» The display Temperature
15
shows the current water temperature.
» The display me/mer
24
shows the current me.
Operang modes
By pressing the buon Mode/key lock
14
the heat pump switches between the operang modes. The set water
temperature can be between +10°C and +45°C.
The heat pump has the following operang modes:
1. Operang mode heang
The heat pump heats the pool water to the set temperature.
2. Operang mode cooling
The heat pump cools the pool water to the set temperature.
3. Operang mode auto
The heat pump regulates the temperature of the pool water by heang or cooling it to the set target
temperature.
4. Operang mode defrost
At low ambient temperatures, the temperature at the heat exchanger can drop so low in heang mode
that the condensaon water freezes and the heat exchanger ices up. The heat pump monitors the
temperature at the heat exchanger and defrosts automacally if necessary.
F
12
24
15
14
Acve display elements in operang mode:
» Operang mode: The display defrost-mode
19
, cooling-mode
20
, automac-mode
21
or heang-
mode
22
lights up.
» Power level: The display silent-mode
16
, smart-mode
17
or power-mode
18
lights up.
» The display temperature
15
shows the current water temperature at the water connecon input
7
(In)
or, ashing, the set brine temperature (set).
» The display mer ON/OFF
23
provides informaon about the me control. If the symbol 1lights up,
mer 1 is acvated. If the symbol „2lights up, mer 2 is acvated
» The display me/mer
24
displays the current me.
Power levels
By pressing the buon power level
10
the heat pump switches between the silent, smart and power performance
levels of the heang and cooling operang modes.
There are 3 power levels to choose from for each of the heang and cooling operang modes:
1. Power level silent
The heat pump minimizes noise development.
This power level reduces the cooling and heang output.
2. Power level smart
The heat pump opmizes the output required to reach the set target temperature through stepless control.
This output level oers the best compromise between energy saving and the me it takes to reach the set
target temperature.
3. Power level power
The heat pump operates at maximum output.
This power level minimizes the cooling and heang me of the pool water.
Save energy
To reduce energy consumpon and the associated costs, you can take the following measures:
» If you do not use the pool for more than a week, switch o the heat pump or reduce the set water
temperature.
» Do not use the heat pump if the ambient temperature falls below 5°C.
» Cover the pool to protect it from heat loss.
G
10
24
23
16
15
17 18 19 20 21 22

Bekijk gratis de handleiding van Steinbach Silent 9, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkSteinbach
ModelSilent 9
CategorieNiet gecategoriseerd
TaalNederlands
Grootte6137 MB