Steinbach Immersion 041055 handleiding

88 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 12 van 88
12
041055Y_V2412
en
Troubleshoo ng
Problem: Cause: Solu on:
Pump motor does
not start
» The Drainage pump is not
connected to the socket.
» The residual current circuit
breaker of the mains
socket has been triggered.
» The mains socket fuse has
tripped
» Pump motor is too
hot and the overload
protec on has been
ac vated.
» Make sure that the appliance is connected to the
socket.
» Reset the residual current circuit breaker of the
mains socket. If the problem persists, contact a
qualifi ed electrician to have the socket checked.
» Reset the fuse. If the problem persists, contact
contact a qualifi ed electrician to fi nd and rec fy the
electrical fault.
» Do not allow the pump to run dry; allow the motor
to cool down for 30 minutes.
Does not pump
water or the
water fl ow is very
slow
» There is air in the pump
and in the hose.
» Deposits clog the
underside of the drainage
pump.
» Pool water is too
contaminated with large
foreign bodies.
» Pump is not si ng upright
on the pool fl oor.
» Water level is lower than
the base of the drainage
pump.
» Allow the air to escape completely from the pump
and the hose.
» Remove all deposits from the pump base.
» Remove large debris and par cles from the pool
oor and surface by fi rst using a skimmer or leaf
net and then draining the pool water.
» Ensure that the pump is always upright.
» Disconnect the mains plug from the socket if the
water level in the pool is lower than the pump base.
If the fault cannot be rec ed,
contact the customer service indicated on the last page..