30 - en
* depending on equipment variant
5.2 Conguring settings
5.2.1 Set lter cleaning mode*
The vacuum cleaner is equipped with an electromagnetic lter
cleaning system that shakes off any dust clinging to the pleated
lter cassettes.
Filter cleaning takes place automatically in the next work break
when the set minimum volume ow is reached (switch position
>AUTO<).
Set the desired mode on the lter cleaning rotating switch (see
chKap. 3 „Display and control elements“ on page 27).
Information on manual cleaning can be found in chapter 5.4.3.
5.2.2 Set hose diameter *
l CAUTION!
Preselector switch for minimum volume ow signal (horn
and light for dust class "M" vacuum cleaners)
If the incorrect hose diameter is set, the warning function will not
work as intended when the suction power decreases.
Set the hose diameter correctly.
For class M vacuum cleaners, set the hose diameter with the
switch:
Preselector switch for
inner hose diameter
Flow rate
42 mm
100 m³/h
35 mm
73 m³/h
32 mm
58 m³/h
27 mm
41 m³/h
15 mm
13 m³/h
5.3 Switching on the vacuum cleaner
The vacuum cleaner is switched on using the control dial for
operating mode / speed.
Two operating modes are available in which the suction power can
be regulated in 3 stages:
Set the control dial to the desired speed level in the >ON<
range.
The vacuum cleaner starts up immediately.
or:
Set the control dial to the desired speed level in the >AUTO<
range.
The vacuum cleaner is in standby mode for power tools
(only in conjunction with cordless control*)
5.4 Vacuuming
l WARNING!
Risk of re! Explosion hazard! Risk of electric shock!
Observe the safety instructions in chapter 2.
5.4.1 Dry vacuuming
Only vacuum with a dry lter, vacuum cleaner and accessories
to prevent dust from sticking and becoming encrusted.
For vacuuming soot, cement, plaster or similar dust: Insert the
PE emptying bag into the dust container.
Always use lter bags in conjunction with pleated lter
cassettes.
NOTE
Class M vacuum cleaners should preferably be used as dry
vacuum cleaners.
5.4.2 Wet vacuuming
l WARNING!
Risk of electric shock!
If foam or liquid is leaking out, switch off the vacuum cleaner
immediately. Empty the container and pleated lter cassette.
NOTE
1
1
Clean the water level sensors (1) and
check for signs of damage regularly.
Vacuum without a non-woven lter bag.
The pleated lter cassettes are suitable for wet vacuuming.
The built-in sensor switches the motor off when the container is
full. The handling of the vacuum cleaner can be impaired by a
full container.
Empty the container (see chKap. 5.5 „Removing the vacuumed
material“ on page 31).
NOTE
If the vacuum cleaner is not switched off, the restart protection
remains effective. The vacuum cleaner is only ready for operation
again after it has been switched off and back on again.
Before emptying, rst remove the suction hose from the liquid.
Due to the high suction power and streamlined container shape,
some water may run back out of the hose after switching off.
Use dry lters for subsequent dry vacuuming.

Bekijk gratis de handleiding van Starmix ISC Batrix L 36-18V, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkStarmix
ModelISC Batrix L 36-18V
CategorieStofzuiger
TaalNederlands
Grootte22395 MB