Stamos S-PLASMA 70-IGBT handleiding
Handleiding
Je bekijkt pagina 6 van 23

10 11
28.09.202128.09.2021
EN
3. OPERATION NOTES
3.1. GENERAL NOTES
•  The device must be applied according to its purpose, 
with observance of OHS regulations and restrictions 
resulting from data included in the rating plate (IP 
level, operation cycle, supply voltage, etc.).
•  The  producer  does  not  bear  any  responsibility  for 
technical  changes  in  the  device  or  material  losses 
caused by the introduction of the said changes.
•  In  case  of  incorrect  device  operation,  contact  the 
service centre.
•  Do not block the ventilation slots - place the device 
20cm  from  the  wall  and  30cm  from  surrounding 
objects.
•  The tilt of the surface on which the device is placed 
should not exceed 15 degrees.
•  Protect the device against rain, moisture and direct 
sunlight.
•  Do not direct sparks onto the device. 
•  Do not hold the device under your arm or near the 
body.
•  The  device  must  not  be  installed  in  rooms  with 
aggressive  environments,  high  dustiness  and  near 
devices with high electromagnetic eld emission.
•  Keep  ngers,  hair,  and  clothing  away  from  the 
rotating fan.
•  The plasma cutter must be earthed for operation.
•  If the thermal overload LED lights up while you are 
working with the device, stop working immediately 
and wait for the device to cool down.
•  When the plasma cutter is used for a long time  or 
with a high current, turn the power o only after the 
device has cooled down.
•  Do not turn o the plasma cutter while cutting!
•  Regularly maintain the device and clean the interior 
of dust.
WORK CYCLE:
The  duty  cycle  is  the  percentage  of  the  operating  time 
(measured  in  minutes)  of  a  10-minute  period  in  which 
the machine is  used  continuously  in normal temperature 
conditions. If the values of the duty cycle are exceeded, this 
will trigger the overheat protection function, which stops 
the machine until it  is  cooled  down to normal operating 
temperature.  Repeated  situations  of  exceeding  the  duty 
cycle values may lead to serious damage of the machine.
3.2. CONNECTING THE POWER
•  Connecting  the  device  must  be  performed  by  a 
qualied person. In addition, a person with required 
qualications  should  check  if  the  earthing  or 
electrical  installation  with  protection  system  is  in 
line with the  safety regulations and if they operate 
correctly.
•  The device must be placed near the work station.
•  Connection  of  excessively  long  conduits  to  the 
machine  must  be  avoided.  Too  long  wires  with  a 
small  cross-section  will  cause  voltage  drops  and 
incorrect operation of the device.
2. TECHNICAL DATA
Parameter 
description
Parameter value
Product name PLASMA CUTTER
Model
S-PLASMA  70-
IGBT
S-PLASMA 100-
IGBT
Rated voltage [V~] / 
Frequency [Hz]
400/50
Cutting current  30-70A 30-100A
Eciency 85% 85%
Power factor 0.93 0.93
No-load voltage [V] 300 250
Rated duty cycle 40% 60%
Cutting current at 
100% duty cycle
44A 50A
Insulation F  F
Protection rating IP IP21S IP21S
Maximum cutting 
thickness (carbon 
steel) [mm]
25 35
Arc ignition HF HF
•  Single phase plasma cutters should be connected to 
a socket equipped with a grounding pin.
  PLEASE  NOTE:  THE  DEVICE  MAY  ONLY  BE  USED 
UPO  CONNECTION  TO  AN  INSTALLMENT  WITH  A 
PROPERLY FUNCTIONING FUSE!
  CAUTION:  When  using  an  electric  generator,  the 
cutter  should  be  disconnected  from  the  power 
supply when starting it!
4. DEVICE CONSTRUCTION
EN
1.3. PERSONAL PROTECTION EQUIPMENT 
ATTENTION! Splinters and sparks may cause injuries.
a)  Always wear a protective mask with side shield.
b)  Always wear appropriate protective clothes in order 
to protect your body.
c)  Always  wear  earplugs  or  other  hearing  protection 
in order to prevent the splinters from entering your 
ears.
d)  The  electric  arc  in  the  cutting  process  generates 
large amounts of both visible and invisible radiation 
(ultraviolet and infrared radiation) that can damage 
the eyes and skin.
e)  During plasma-cutting, it is required to wear clean, 
oil-free protective clothes, e.g.: leather gloves, thick 
shirt, high boots and protective hood 
f)  Always use face protection (helmet or shield) and eye 
protection with glass with appropriate tint, acting as 
lter and protecting the eyes during cutting.
g)  Safety  standards  propose  tint  no.  9  (no.  8  at 
minimum) for  every  current intensity  below  300  A. 
A lower shield tint may be used if the arc covers the 
workpiece.
h)  Always use permitted safety goggles with side shield 
under the helmet or another protection.
i)  Use  workplace  shields  in  order  to  protect  other 
people against blinding light or splinters. 
j)  Warn bystanders not to look at the electric arc.
k)  It  is  not  recommended  to  use  the  device  without 
prior  consultation  with  a  doctor  by  people  with  a 
pacemaker or other implanted medical device.
1.4. PROTECTION AGAINST ELECTRIC SHOCK 
ATTENTION! Electric shock can be lethal!
a)  The power cable must be connected to the nearest 
socket and placed in a practical and secure position. 
Positioning the cable negligently in the room and on 
a surface which was not checked must be avoided, as 
it can lead to electrocution or re.
b)  Touching  electrically  charged  elements  can  cause 
electrocution or serious burns.
c)  The electrical arc and the working area are electrically 
charged during the power ow.
d)  The  input  circuit  and  inner  power  circuit  of  the 
devices  are  also  under  voltage  charge  when  the 
power supply is turned on.
e)  The elements under the voltage charge must not be 
touched.
f)  Dry,  insulated  gloves  without  any  holes  and 
protective clothing must be worn at all times.
g)  Insulation mats or other insulation layers, big enough 
as not to allow for body contact with an object or the 
oor, must be placed on the oor.
h)  The electrical arc must not be touched.
i)  Electrical power must be shut down prior to cleaning 
or electrode replacement.
j)  It must be checked if the earthing cable is properly 
connected or the pin is correctly connected  to  the 
earthed  socket.  Incorrect  earthing  connection  can 
cause life or health hazard.
k)  The  power  cables  must  be  regularly  checked  for 
damage or lack of insulation. Damaged cables must 
be  replaced.  Negligent  insulation  repair  can  cause 
death or serious injury.
l)  When  the  product  is  not  in  use,  turn  o  all  input 
power supplies.
m)  The cable mustn’t be wrapped around the body.
n)  The  object  which  is  being  cut  must  be  properly 
grounded.
ATTENTION!  Electric  arc  radiation  may  damage 
eyesight and skin.
ATTENTION!  The  device can  still  be  under  voltage 
upon feeder disconnection.
ATTENTION!  Despite  the safe design of the  device 
and  its  protective  features,  and  despite  the  use  of 
additional elements protecting the operator, there is 
still a slight risk of accident or injury when using the 
device. Stay alert and use common sense when using 
the device.
o)  Only equipment in good condition can be used.
p)  Damaged  device  elements  must  be  repaired  or 
replaced. 
q)  Safety belts must be used when working at height.
r)  All ttings and safety elements must be stored in one 
place.
s)  From  the  moment  of  turning  on  the  release,  the 
handle end must be kept away from the body.
t)  Attach  the  operating  cable  to  the  proper  metal 
contact of the element being cut (not to the element 
that may fall o) or to the work table close  to  the 
plasma cutter as much as needed.
u)  The  working  clamp  is  to  be  insulated,  unless  it 
is  connected  to  the  workpiece,  in  order  to  avoid 
contact with metal.
v)  The product is intended for indoor use. However, if 
it has been exposed to moisture or rain, you should 
check  if  water  droplets  have  fallen  in,  which  may 
result in an accident. 
w)  The voltage in the input capacitor must be checked 
upon  turning  o  the  device  and  disconnecting  it 
from the power source. One must make sure that the 
voltage value is equal to zero. Otherwise, the device 
elements must not be touched.
x)  Do not get the device wet.
Air supply pressure 
[bar]
3.9 - 4.9 3.9-5.9
Dimensions [Width 
x Depth x Height; 
mm]
220 x 560 x 405 260 x 620 x 380
Weight [kg]  18.9 31
Technology IGBT IGBT
1
2
3
4
5
6
10
987
1 - Overheating LED
2 - Power LED
3 - Current adjustment knob
4 - Ammeter
5 - 2T/4T mode switch
6 - GAS (gas test)/CUT (cutting) mode switch
7 - Ground wire connector
8 - Burner arc ignition connector 
9 - Switch connector
10 - The gun gas supply connection
Bekijk gratis de handleiding van Stamos S-PLASMA 70-IGBT, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Stamos | 
| Model | S-PLASMA 70-IGBT | 
| Categorie | Niet gecategoriseerd | 
| Taal | Nederlands | 
| Grootte | 5125 MB | 