Stamos S-MMA 250 IGBT handleiding
Handleiding
Je bekijkt pagina 15 van 56

15
Rev. 03.01.2018
EN
10. TROUBLESHOOTING
Problem Troubleshooting
Electric source indicator doesn’t light.
Fan doesn’t run. No welding output
1. Check power switch.
2. Check input wires.
Electric source indicator lights but the fan
doesn’t run or stop for a while. No welding
output.
1. Connected with wrong electric source. Change the
connection into single 230V.
2. 230V power system is unstable.
3. Power off and power on continuously in a short time
and cause the over-voltage protection.
4. Wire which connects switch and electrical source is
loose. Fix it.
Fan is running but output current is
unstable or cannot been controlled by
potentiometer.
1. Problems with the potentiometer;
2. Some connecting terminals aren’t xed correctly.
Fan runs but problem indicator doesn’t
light. No welding output.
1. Check all plug-ins are in good connection.
2. Check if the output terminals are open or loosely
connected.
The problem indicator light and fan are
running, but no welding output.
1. Over-current protection activated. Power off rst then
power on again.
2. Overheat protection activated. Normal operation will
resume after waiting for 2 minutes to 3 minutes