Speed Queen FV6010WN handleiding
Handleiding
Je bekijkt pagina 116 van 119

Power Fail Recovery
The Power Fail Recovery feature allows the cycle status to be
saved in memory in the event of a power failure.
If the power failure lasted less than 7 seconds and the door is
locked, the cycle will resume without requiring the user to press
the START (enter) keypad to restart.
If the power failure lasted longer than 7 seconds, the Power Fail
Reset option is turned on, and the duration of the power failure is
less than or equal to the time programmed in the Power Fail Re-
set option, the door is unlocked and the START (enter) keypad
will flash until it is pressed and the cycle will restart from the
point it left off.
If the power failure lasted longer than 7 seconds and the Power
Fail Reset option is turned oFF, the door is unlocked and the
START (enter) keypad will flash one second on and one second
off until it is pressed. The cycle will restart from the point it left
off when START (enter) is pressed.
If the power failure lasted longer than 7 seconds, lasted longer
than the time programmed in the Power Fail Reset option, and the
Power Fail Reset option is turned on, the control will reset the
cycle and lose all vending entered for the cycle.
Power Fail Recovery
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
116 Part No. 807870ENR4