Specifications
Charging time
The time to charge a completely exhausted battery pack to
its full capacity is shown in the table below (when charging
a battery pack at a temperature of 25°C (77°F)).
Up to four battery packs can be charged simultaneously in
the amount of time shown in the table.
About the charge indicators
The charge indicators show the charging status of the
inserted battery packs, as shown in the table below.
When an abnormality is detected while
charging
When one of the following conditions is detected while
charging, the charge indicator flashes in orange and green
alternately, and charging is canceled to protect the battery
pack.
• After the start of charging, the voltage of the DC output
for battery charging has dropped below the specified
level (6 V).
• After the start of charging, the voltage of the DC output
for battery charging has exceeded the specified level
(17.5 V).
• The battery voltage did not rise to the specified level
within a specified period of time (2 hours).
When an abnormality is detected, the battery pack may be
defective. Do not use that battery pack.
When the internal fan has stopped, all charge indicators
also flash in orange and green alternately at the same time.
The charge indicator remains flashing until the a side of
the POWER switch is pressed, the AC power cord is
disconnected, or the battery pack is removed.
• When a battery pack that is not chargeable with the BC-
L500 is connected, charging does not take place.
• The BP-M50/M100 (nickel metal hydride battery packs)
cannot be charged with the BC-L500.
Note on the battery packs
Performance of the BC-L500 is guaranteed only for Sony
lithium-ion batteries.
Specifications
General
Voltage source 100-240 V AC, 50/60 Hz
Current drain 480 VA
Peak inrush current
(1)Power ON, current probe method:
15 A (100 V)/34 A (240 V)
(2)Hot switching inrush current measured
in accordance with European standard
EN55103-1: 18 A (230 V)
Operating temperature
0°C to 45°C (32°F to 113°F)
Mass Approx. 5.6 kg (12 lb 6 oz)
Dimensions (w/h/d)
435 × 124 × 235 mm (17
1
/
4
× 5 × 9
3
/
8
inches) (excluding projecting parts)
Input/Output
Current input (AC)
480 VA
Voltage output (DC)
16.4 V (5 A/3 A)/16.8 V (5 A/3 A)
(square-shaped 5-pin connector)
Supplied accessories
Operation manual (1)
AC power cord (U.S.A. only) (1)
Plug holder (1)
Designs and specifications are subject to change without
notice.
Battery pack Charging time to full capacity
BP-FLX75 About 110 minutes
Indicator status Charging status
Flashing in orange In progress (charged less than
80%)
Flashing in green In progress (charged 80% or
more)
On in green Charging completed
Flashing in orange and
green alternately
An abnormality has been
detected during charging. (For
details, see “When an
abnormality is detected while
charging” below.)
Notes
Bekijk gratis de handleiding van Sony BC-L500, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Sony |
| Model | BC-L500 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 7401 MB |
Caratteristiche Prodotto
| Kleur van het product | Zwart |
| Gewicht | 5600 g |
| Breedte | 435 mm |
| Diepte | 230 mm |
| Hoogte | 124 mm |