WARNING: If the FIL-PILOTE interface does not use the FP wire (black), it must be
secured from access to the other wires.
DO NOT CONNECT the “FP” wire to GROUND TERMINAL.
CONNECTION OF THE DEVICE IN M/MS VERSION (WITHOUT POWER CORD)
DEVICE DISASSEMBLY
1. Disconnect the device from electricity.
2. Release the screw at the back of the controller casing.
3. Take off the casing.
4. In case of a radiator connected to a central heating system, close the valves
and remove the heating medium. For electric radiators – take it off the wall and
position it in such a way to prevent the heating medium from pouring out of the
radiator during disconnecting the heating element.
Untwist the heating element using spanner no
MAINTENANCE
1. Disconnect the device from electricity prior to cleaning.
2. Heating element controller should be cleaned with a dry or damp cloth with
a very small amount of detergents, which should never contain any solvents or
abrasive agents.
External
Fil-Pilote
Driver
L
N
FP
L
N
FP
L
N
1 2
3a
3b
L
N
PE
5 6
7
8
4
2. Insert the heating element (1) into the threaded opening in the tee piece,
integrated valve or directly into the radiator, depending on the required
connection type.
3. Twist the head of the heating element using a spanner no 24.
4. Position the element in such a way so that the indent in the head connection
(A) was directed towards you or sideways.
5. Open the valves, fill the radiator with heating medium from the installation and
bleed it.
6. Make sure that the connection between the radiator and the heating element
unit is tight.
7. Install the controller – fit the indents on the head (A) with the indents in the
controller (B).
8. Position the controller casing in a way providing an easy and comfortable
access.
WARNING! If you feel resistance when twisting the controller that means that you
have reached the maximum twisting span in that direction. Try to twist the controller
in the opposite direction. Any damage to the device will result in annulment of the
warranty.
Correctly installed controller entirely covers the head of the heating
element (see drawing)
9. Secure the casing at the back with Allen key.
10. Close one of the valves before using the heating element unit and leave the
other one open (we suggest that you close the thermostatic valve). Always
make sure that one of the valves is open prior to the use of heating element
unit!!
11. Connect the heating element unit to the socket / installation. The device is
ready for use.
INSTALLATION OF THE DEVICE WITH FIL PILOTE INTERFACE
SKT controller has an additional wire for connecting an external FIL-PILOTE
controller.
Installation scheme of the correct connection of SKT controller as well as an
external FIL-PILOTE controller:
A
7
B
max.
340º
8
9
Colour codes of wires in electric cord:
Brown
Live (L)
Blue Neutral (N)
Black FIL-PILOTE wire (FP)