Sonnenkonig BKT 1 handleiding
Handleiding
Je bekijkt pagina 34 van 49

TECHNICAL INFORMATION
Model Code
(type of power wire)
– PW (straight cable with plug)
– PB (double-string straight cable without plug)
– PB-FP6 (triple-string straight cable without plug
with FIL-PILOTE interface)
– M*) (masking cover)
– MS*) (masking cover + on/off switch)
*available only for SKT 1
Electric supply 230 V / 50 Hz
Heating outputs
available
200, 300, 400, 600, 800, 1000 W
Insulation class
II class
Radiator connection G 1/2"
Casing protection mark
IPx4 : SKT 1
IPx5 : SKT 2, SKT 3, SKT 4
Electric connection type
Y type: versions –PW
X type: versions –M and –MS
Device permanently connected to installation:
versions –PB, –PB (FP6)
Temperature measured:
Room temperature
Our products have been designed and manufactured in such a way to ensure that
all the quality, functionality and aesthetic requirements are met. We would like to
congratulate You on this great purchase and would like to wish You a pleasant use.
SAFETY REGULATIONS
Please read the below instructions thoroughly and study the images carefully.
1. Never use the device that is damaged in any way.
2. Please check if the tally voltage equals the voltage of the
electric installation in your home prior to connecting the
device.
3. Please check regularly if the power wire is not damaged and
if the device can be used in a safe manner.
4. Power wire is not subject to repair. Damaged power wire should be
replaced at the manufacturer's or specialised repair shop.
5. For devices without the plug (ie. connected directly to installation), please see
below colour codes for each wire:
*only in selected models
6. Heating element is intended to work in a liquid medium environment. It is
advised not to turn the device on in dry conditions for longer than 5 seconds.
Do not touch metal parts – burning risk. Always make sure that the wire does
not touch the heating element that is hot.
7. The device must not be connected while being installed. Unplug the device or
disconnect the power wire from electrical circuit. Put the casing on the body of
the heating element unit before plugging the device.
8. In order to assure reliable operation of the device, please make sure that
the controller is properly secured at the back with Allen key.
9. Do not open the casing.
10. Heating element's electric output cannot exceed suggested heating
output of the radiator for the following parameters: 75/65/20°C.
11. Pressure inside the radiator must not exceed the pressure value
recommended by the radiator's manufacturer or the pressure of 15
atmospheres for the heating element. Exceeding of recommended pressures
may result in the radiator or heating element damage and cause possible
threat for health, life and property.
12. An air pillow of the correct parameters should always be allowed for inside an
electric radiator (see → Installation).
13. In case of a dual fuel radiator (connected to the central heating system) one of
the valves should be left open prior to turning the heating element on and
during its operation in order for the excess water created due to its heat
expansiveness to be pushed out. Leaving both valves closed will result in
excessive pressure growth which may lead to damaging of the heating element
or radiator.
14. The device is intended for domestic use.
15. The device is not intended for use by children, persons with limited mental
capacity or those who do not have sufficient knowledge or experience required
for handling this type of equipment. In such cases, control or training by
persons responsible for safety of the above mentioned is required.
INTENDED USE OF DEVICE
Terma heating elements and control heads are electric heating devices and are
intended for installation and use in radiators used for heating interior spaces or
drying towels or clothes. Heating element and control head can be installed in a
radiator connected to the central heating system for use during the heating season
as well as in an individual electric radiator.
Heating elements are intended solely to operate in containers which are not open to
the atmosphere.
EN
COLOUR LETTER CODE WIRE TYPE
Brown L Live
Blue N Neutral
Black* F-P Controlling wire