42
Safety information for
troubleshooting
DANGER!
If there is direct or indirect contact with live parts,
dangerous current could ow through the body.
Electrical shock, burns, or death may result.
¾ Before performing wiring work, make sure that the
lines are de-energised. During wiring work, make
sure that the lines remain de-energised (e.g. prevent
reactivation).
¾ Connection to the mains power must be performed
by the personnel described in the chapter
"Qualications of personnel" on page 6.
Changing the fuse
1. De-energise the barrier and secure it against reactivation.
2. Open the barrier housing.
3. Open the control unit housing.
4. Change the defective fuse (1 A fast-acting fuse).
5. Closing the control unit housing.
6. Close the barrier housing.
Replacing springs
RISK OF CRUSH INJURIES TO HANDS!
Risk of crushing at the lever system of the barrier when
the hood and door of the barrier housing are open!
¾ All work on the barrier must be carried out by qualied
personnel!
¾ Before working on the barrier, always disconnect
the system and secure it to prevent reactivation!
¾ Install the barrier housing without the boom!
¾ Follow the instructions on personal protective
equipment!
INFORMATION:
To ensure problem-free operation, we recommend that
you replace both springs!
1. De-energise the barrier and secure it against reactivation.
2. Open the door of the barrier housing and release the lock of the cover.
3. Remove the top cover of the barrier.
1
2
3
4. Loosen both nuts of the broken springs.
5. Remove the broken springs.