Unless specified otherwise, default test configuration:
Sample Rate: 48kHz, Bandwidth: 20 Hz to 20 kHz
Measurement device output impedance: 40 Ω (20 Ω unbalanced)
Measurement device input impedance: 200 kΩ (100 kΩ unbalanced)
Unless otherwise quoted all figures have a tolerance of ±0.5dB or 5%
Microphone Inputs
Frequency Response: ± 0.1 dB
Dynamic Range (A-Weighted): 116.5 dB
THD+N (@ 1kHz): -100 dB / < 0.001 % @ -8 dBFS
EIN (A-Weighted, 150 Ω termination): -130.5 dBu
Maximum Input Level: +9.7 dBu
Gain Range: 64 dB
Input Impedance: 1.2 kΩ
Line Inputs
Frequency Response: ± 0.05 dB
Dynamic Range (A-Weighted): 117 dB
THD+N (@ 1kHz): -104 dB / < 0.0007 % @ -1 dBFS
Maximum Input Level: +24 dBu
Gain Range: 27dB
Input Impedance: 14 kΩ
Instrument Inputs
Frequency Response: ± 0.05 dB
Dynamic Range (A-Weighted): 116 dB