8 Troubleshooting
Check the indicators (refer to the “7.3 Status Indicators“) to determine the status
of T-BAT SYS-HV.
In case the following circumstance occurs, for instance, voltage or temperature
exceeding the limit, a warning state will be triggered.
T-BAT system’s BMS will periodically report its operating state to inverter.
In case the T-BAT SYS-HV exceeds the specific limit, it will enter a warning state.
And if the warning is reported, the inverter will stop working immediately.
Please use the monitoring software on the inverter to check the cause of
warning.
The possible error information is shown as follows:
Error Description Diagnosis & Solution
BMS_External_Err
External fault of
BMS
Unable to establish communication
with inverter:
■
Restart BMS;
■
Contact the company’s after-sales
personnel.
BMS_Internal_Err
Internal fault of
BMS
Unable to establish communication
with inverter:
■
Restart BMS;
■
Check whether the connection
among batteries is normal;
■
Contact the company’s after-sales
personnel.
BMS_OverVoltage BMS overvoltage
Overvoltage of single battery.
■
Contact the company’s after-sales
personnel.
BMS_LowerVolatge BMS undervoltage
Undervoltage of single battery.
■
Battery is forced to charge through
inverter;
■
Contact the company’s after-sales
personnel.
BMS_ChargeeOverCurrent
Overcurrent
charging of BMS
Overcurrent charging of BMS.
■
Restart BMS;
■
Contact the company’s after-sales
personnels.
BMS_DischargeOverCurrent
Discharge
overcurrent of
BMS
Discharge overcurrent of BMS.
■
Restart BMS;
■
Contact the company’s after-sales
personnel.
BMS_TemHigh
High temperature
of BMS
The temperature of BMS is too high.
■
Let BMS cool down to normal tem-
perature and restart;
■
Contact the company’s after-sales
personnel.