3.2 ACCESS TO INSTALLER’S INFORMATION
For access to information for the installer, press the key
5
3
1
2
4
(3 fig. 12). Every time the key is pressed, the display moves to the next
item of information. If the key
5
3
1
2
4
is not pressed, the system automatically quits the function. If there is no expansion board (MIXED
ZONE or SOLAR) the relative info will not be displayed. List of information:
1. Visualizzazione temperatura esterna
solo con sonda esterna collegata
2. Visualizzazione temperatura sonda
mandata riscaldamento (SM)
3. Visualizzazione temperatura sonda
sanitario (SS) solo per caldaie istantanee
4. Visualizzazione temperatura sonda
ausiliaria o sonda bollitore (SB)
6. Visualizzazione temperatura
riscaldamento riferita al primo circuito
7. Visualizzazione temperatura
riscaldamento riferita al secondo circuito
9. Visualizzazione numero giri ventilator
e in rpm x 100 (es. 4.800 e 1.850 rpm)
10. Visualizzazione ore di funzionamento del bruciator
e in h x 100 (es. 14.000 e 10)
11. Visualizzazione numero di accensioni del bruciator
e x 1.000 (es. 97.000 e 500)
5. Visualizzazione temperatura sonda
fumi (SF)
8. Visualizzazione corrente
di ionizzazione in µA
17. Visualizzazione portata sanitaria flussimetro (es. 18 l/min
e 0,3 l/min) o stato flussostato (rispettivamente ON e OFF)
12. Visualizzazione numero totale
delle anomalie
13. Contatore accessi parametri
installatore (es. 140 accessi)
14. Contatore accessi parametri
OEM (es. 48 accessi)
15. Contatore accessi parametri
CASCATA OEM (es. 05 accessi)
2. Display of Heating flow sensor (SM)
3. Display of D.H.W. temperature sensor (SS)
only for instantaneous boilers
4. Display of auxiliary temperature sensor
or D.H.W. sensor (SB)
6. Display of heating temperature of first
circuit
7. Display of heating temperature of second
circuit
8. Display of ionisation current in µA
10. Display of hours of functioning of the burner in h x 100 (e.g. 14000 and 10)
11. Display of number of times the burner has ignited x 1000 (e.g. 97000 and 500)
12. Display of total number
of errors
5. Display of exhaust temperature sensor
(SF)
13. Parameter access counter–
Installer (i.e. 140 accesses)
14. Parameter access counter–OEM
(i.e. 48 accesses)
1. Display of external temperature, only
with external sensor connected
9. Display of fan speed in rpm x 100 (e.g. 4.800 and 1850 rpm)
15. Parameter access counter–
CASCADE OEM (i.e. 05 accesses)
17. Display of D.H.W. flowmeter load (i.e. 18 l/min and 0.3 l/min) or flow switch
(respectively ON and OFF) (Not this boiler)