3 SPECIFICATIONS
SIME FUEL
SIME FUEL 25 EV
(vers. std)
SIME FUEL 35 EV
(vers. std)
SIME FUEL 25 EV
(vers. HE)
SIME FUEL 35 EV
(vers. HE)
Heat output set in the factory
(1)
kW 27 34,8 27 34,8
kcal/h 23,220 29,928 23,220 29,928
Heat capacity set in the factory
(1)
kg/h 2,25 2,9 2,25 2,9
Fuel
(2)
Diesel, viscosity 1.6–6 mm
2
/s a (Hi=12.01 kWh/kg)
NOx emissions
< 120 mg/kWh
[in accordance with Regulation (EC) No. 813/2013 and the EN 267:2020
standard Class 4] < 120 mg/kWh
[in accordance with Regulation (EC) No. 813/2013 and the EN 267:2020
standard Class 4]
Control and command equipment EBR - M14 R 15-15
Flame sensor EBR FTEB (Black)
Ignition transformer Fida 2P 26 kV pp-35 mA rms
Fuel oil pump Suntec ALV 35A
Pump coil 871 T80
Electric motor
EBR 90 W, 2800 rpm
watt 90
Capacitor Inco 4 μF, TEKNO 45T (T = top series)
Power supply 1 / 230 / 50 Ph / V / Hz
Power input (during operation) (+/- 5W) W 183 181
Electrical protection IP IP40
Sound pressure level dB(A) 65
Storage room temperature °C -20 ... +70
Operating temperature °C -10 ... +60
(1)
Reference conditions: Room temperature 20 °C – Barometric pressure 1013 mbar – Altitude 0 m.a.s.l..
m
CAUTION
(2)
The burner is suitable for use with diesel containing a biofuel blend of up to 10%. A minimum requirement for biofuel
blends (up to 10%) is that they be obtained with diesel in accordance with the applicable standards and in conformity to the
local regional regulations.
If the biofuel contains an organic blend above 10%, contact the manufacturer.