ID Gas Nz Qn (kW) m
3
/h g/h Bp M
G20/25mbar 91 1,75 0,167 - 32 B
G25/20mbar 100 1,75 0,194 - 32 B
G25/25mbar 95 1,75 0,194 - 32 B
G25.1/25mbar 95 1,60 0,177 - 32 B
G25.3/25mbar 95 1,75 0,19 - 32 B
G30/29mbar 66 1,75 - 127 32 A
G30/37mbar 61 1,75 - 127 32 A
G30/50mbar 58 1,75 - 127 29 A
G31/37mbar 66 1,75 - 125 32 A
G20/20mbar 128 3,00 0,286 - 39 B
G20/25mbar 120 3,00 0,286 - 39 B
G25/20mbar 134 3,00 0,333 - 39 B
G25/25mbar 126 3,00 0,333 - 39 B
G25.1/25mbar 126 2,80 0,31 - 39 B
G25.3/25mbar 126 3,00 0,325 - 39 B
G30/29mbar 87 3,00 - 218 39 A
G30/37mbar 80 3,00 - 218 39 A
G30/50mbar 75 3,00 - 218 35 A
G31/37mbar 87 3,00 - 214 39 A
G20/20mbar 138 3,50 0,334 - 61 B
G20/25mbar 130 3,50 0,334 - 61 B
G25/20mbar 143 3,50 0,388 - 61 B
G25/25mbar 136 3,50 0,388 - 61 B
G25.1/25mbar 136 3,30 0,365 - 61 B
G25.3/25mbar 136 3,50 0,379 - 61 B
G30/29mbar 90 3,30 - 240 61 A
G30/37mbar 84 3,30 - 240 61 A
G30/50mbar 71 3,30 - 240 55 A
G31/37mbar 90 3,30 - 240 61 A
17
en
Safe installation
Follow these safety instructions when installing the
appliance.
¡ Read this instruction manual carefully.
¡ The images shown in these instructions are for
guidance only.
¡ The appliance can only be used safely if it is cor-
rectly installed according to the safety instructions.
The installer is responsible for ensuring that the
appliance works perfectly at its installation loca-
tion.
WARNING‒Risk of explosion!
Escaping gas may cause an explosion.
▶ All Installation, connection, regulating and conver-
sion work to a different gas type must be carried
out by an authorised professional while taking into
account the respective applicable regulations and
legal requirements as well as the regulations re-
garding the local electricity and gas suppliers.
Special attention must be paid to the provisions
and guidelines that are applicable for the ventila-
tion. For conversion work to a different gas type,
we recommend that you call the after-sales ser-
vice.
¡ Ensure that the kitchen is sufficiently ventilated, in
particular when operating the gas cooking appli-
ance.
¡ Do not connect the appliance to an exhaust gas
system for combustion products.
¡ Never install the appliance in boats or in vehicles.
¡ The warranty applies only when using the appli-
ance as intended.
¡ Before installing the appliance, check that the
local conditions of the supplier are compatible
with the appliance settings specified on the rating
plate (type of gas and pressure, power, voltage).
¡ Secure the power cord to the cabinet to prevent it
from touching hot parts of the oven or hob.
¡ Before any work is carried out on the appliance,
switch off the power supply and the gas supply.
¡ Connect the appliance to the power supply using
the earth.
¡ Do not make any changes to the inside of the ap-
pliance. If required, contact our technical cus-
tomer service.
Before installing
¡ This appliance is a class 3 appliance in accord-
ance with the EN 30-1-1 standard for gas appli-
ances: Built-in appliance.
¡ The unit in which the appliance is installed must
be stable and secured appropriately.
Bekijk gratis de handleiding van Siemens EG6B5HO92R, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Siemens |
| Model | EG6B5HO92R |
| Categorie | Fornuis |
| Taal | Nederlands |
| Grootte | 1875 MB |