52
E
Controlling the Monitor with a PC (RS-232C)
Commands for setting of the GAMMA user data
Function
Command Direction
Parameter Reply Control/Response contents *
RED GAMMA DATA TRANSFER UGRW W aaxxxx
···
xxxxcc
(xxxx: 32 pieces)
aa: 01-16
xxxx: 0000-1023
cc: 00-FF
aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and user data
GREEN GAMMA DATA TRANSFER UGGW W
BLUE GAMMA DATA TRANSFER UGBW W
RED GAMMA DATA READ UGRR W 1-16 xxxx
···
xxxx
(xxxx: 32 pieces)
xxxx: 0000-1023
xxxx: User data of 32 pieces
GREEN GAMMA DATA READ UGGR W 1-16
BLUE GAMMA DATA READ UGBR W 1-16
USER DATA INITIALIZE UGRS W 0 Initialize the user data.
USER DATA SAVE UGSV W 0 Save the user data in the monitor.