TROUBLESHOOTING
Problem Possible Cause Possible Solution
Compressor not running.
Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker.
Power cord unplugged. Plug in power cord.
Thermostat set too high. Set thermostat to lower temperature.
Cabinet in defrost cycle. Wait for defrost cycle to finish.
Condensing units run for long periods of
time.
Excessive amount of warm product
placed in cabinet.
Allow adequate time for product to cool
down.
Dirty condenser coil. Clean the condenser coil (Page 6).
Evaporator coil iced over.
Unplug unit and allow coil to defrost.
Make sure thermostat is not set too cold.
Cabinet temperature is too warm.
Thermostat set too warm. Set thermostat to lower temperature.
Airflow blocked.
Rearrange product to allow for proper
air flow. Make sure there is at least 4
inches of clearance from evaporator.
Excessive amount of warm product
placed in cabinet.
Allow adequate time for product to cool
down.
Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker.
Dirty condenser coil. Clean the condenser coil (Page 6).
Evaporator coil iced over.
Ensure wells are covered when not
in use.
Low refrigerant levels.
Contact a service technician to check
refrigerant levels.
Condensation is collecting on the
cabinet and/or floor.
Relative humidity is above 55%.
Move unit to area below relative
humidity or lower humidity level.